科技论文和展示

这里您可以找到在全球 COMSOL 年会上所有用户报告的演示文稿。这些演示文稿介绍 COMSOL 用户是如何使用 COMSOL Multiphysics 进行创新性研究和产品设计。研究主题涵盖了包括电气、机械、流体和化工等范围广泛的行业和应用领域。请使用“快速搜索”来查找与您的研究领域相关的演示文稿。

Design of MEMS Based High Sensitivity and Fast Response Capacitive Humidity Sensor

R. Karthick, S. P. K. Babu, A. R. Abirami, and S. Kalainila
Periyar Maniammai University
Periyar Nagar
Vallam, Thanjavur
Tamilnadu, India

This paper presents the design and simulation of high sensitivity and fast response capacitive humidity sensor. Generally, the capacitive humidity sensor is made up of parallel electrode, the upper electrode being a grid with various line width and line spacing. A model is simulated using COMSOL Multiphysics. High sensitivity and fast response of the model is optimized by varying the ...

Heat Transfer Modeling and Analysis of a Rotary Regenerative Air Pre-heater

R. K. Krishna, R. Ramachandran, and P. Srinivasan
Birla Institute of Technology and Science
Pilani
Rajasthan, India

An attempt has been made to sustain the efficiency of an air pre-heater(APH) in the long run. The APH is modeled using COMSOL Multiphysics in 3D and fed with real life conditions. Upon Heat transfer analysis, the temperature profile was found out and from that, the regions undergoing maximum thermal fatigue stress was identified. The plates of the APH to the periphery are subjected to maximum ...

Design and Simulation of a Nano-Wire Based Piezoresistive Pressure Sensor

S. A. Selvin, N. B. Moorthy, G. Anju, and M. Alagappan
PSG College of Technology
Coimbatore
Tamil Nadu, India

This paper chalks out the design and performance of a piezo resistive surface micro machined circular diaphragm based pressure sensor. A structural deformation in the piezo resistive nano structure placed above the diaphragm will result in varied current density, which is in direct accordance with the applied pressure. This effect relies on the principle of piezo resistivity and employing a nano ...

Simulation of MEMS based Flexible Flow Sensor for Biomedical Application

D. Maji[1], C. P. Ravikumar[2], and S. Das[1]
[1]School of Medical Science and Technology, Indian Institute of Technology, Kharagpur, West Bengal, India
[2]Texas Instruments (India) Pvt. Ltd., Bangalore, India

Arterial disease, especially Coronary Artery Disease (CAD) is one of the leading causes of premature morbidity and mortality. During the flow, blood interacts with vessel wall mechanically and chemically which modulates the plaque formation in blood vessel leading to coronary artery diseases. Here we propose to simulate a MEMS based flexible flow sensor based on anemometer principle designed to ...

Design, Simulation and Study of MEMS Based Micro-Needles and Micro-Pump for Biomedical Applications

P. K. Podder, D. Mallick, D. P. Samajdar, and A. Bhattacharyya
Institute of Radio Physics and Electronics
University of Calcutta
Kolkata
West Bengal, India

In this paper, we have addressed the issues related to the design and simulation of MEMS based silicon micro-needles for insertion of fluid into the dermis layer and into the subcutaneous fat layer. In addition, a poly-silicon micro-pump based on the principle of electrostatic actuation has been designed and simulated which can be integrated with the proposed micro-needles to control the fluid ...

On the Simulation of Electromagnetic Forming Process of a Tube using Multiphysics Software

S. Gawade[1], P. P. Date[2], and S. B. Sharma[1]
[1]Production Engineering. Dept. SGGS IE&T, Nanded, India
[2]Mechanical Engineering. Dept, IIT, Bombay, India

Electromagnetic forming (EMF) is a typical high speed forming process using the energy density of a pulsed magnetic field to form workpieces made of metals with high electrical conductivity like e.g. aluminium. This forming process can be very advantageous as compared to conventional forming process. EMF process is simulated by a commercial finite element analysis (FEA) solver, COMSOL ...

Design and Simulation of 3D ZnO Nanowire Based Gas Sensors for Conductivity Studies

N. Gouthami, D. Parthiban, M. Alagappan, and G. Anju
PSG College of Technology
Coimbatore
Tamil Nadu, India

The objective of this paper is to design a 3D Gas Sensor for sensing Hydrogen gas and to increase the conductivity at nano level. In this novel design, nanorods act as the sensing layer. The sensitivity towards gas adsorption is found to be increased due to its high surface to volume ratio. The total displacement and voltage on intermediate layer after gas adsorption will be changing by varying ...

Determination of Fundamental Frequency of a Thin Rectangular Perforated Plate using COMSOL Multiphysics

S. V. N. B. Prasad, and B. Raghavendra
BITS PILANI K K BIRLA
GOA CAMPUS, India

COMSOL Multiphysics 4.0 is being used to simulate the free vibrations of a plate. The results obtained by simulation in COMSOL are in close proximity to that found by Fast Fourier Transform analyzer and analytical method. As of now the vibration analysis of thin rectangular plates with perforations in rectangular pattern has been carried out. The study of vibration analysis of thin rectangular ...

3-D Design, Electro-Thermal Simulation and Geometrical Optimization of Spiral Platinum Micro-Heaters for Low Power Gas Sensing Applications Using COMSOL 4.1

V. Bansal, D. Kumar, B. Prasad, and A. Gujjar
Electronic Science Department

In this paper a thermal electric finite element method (FEM) analysis was used to investigate the thermal properties of individual electrically driven platinum micro-heaters. The geometric optimization for the micro-heater was performed by simulating a wide range of possible geometries using COMSOL 4.1. The simulated results of micro-heaters having an improved temperature distribution over the ...

Voltage and Capacitance analysis of EWOD system using COMSOL

D. Das[1], S. Sohail[1], S. Das[2], and K. Biswas[1]
[1]Electrical Engineering Department, IIT Kharagpur, India
[2]School of Medical Science and Technology, IIT Kharagpur, India

Electrowetting on Dielectrics (EWOD)systems is widely practiced digital microfluidic technique, used in Lab-on-a-Chip (LoC) system for biomedical application. In EWOD, with applied potential, the droplet minimizes its surface energy by transiting towards the actuated electrode. The problems with EWOD device for biological sample are that it will damage the cells if applied voltage across it ...

Quick Search